Search & filter
Search & filter
Abstract: To design the ventilation system of a railway tunnel that can handle fire emergencies, the energy released from a railcar fire has to be considered. The maximum heat release rate is particularly important. Traditionally, the Kennedy equation is used to calculate the critical velocity of tunnel fire, which is the minimum ventilation speed required to control smoke and heat originating from the...