Abstract: During the lining construction process, high concentrated thrust jack forces are introduced in the segments leading to both high compressive stresses under the thrust shoes that can provoke a concrete crushing and tensile transversal stresses; the latter can cause cracks and, eventually, a splitting failure. In order to investigate the main mechanisms involved during either splitting or...