Search & filter
Search & filter
Abstract: Site and laboratory testing of sprayed concrete linings waterproofed with spray-applied membrane has been carried out over a period of 3 years. The site testing has been carried out in several full scale test sections as well as a longer section of a rail tunnel in hard rock in Norway. The linings were tested for moisture content and tensile bonding strength. The results of the site testing...